{"id":2007,"date":"2024-05-23T16:29:26","date_gmt":"2024-05-23T08:29:26","guid":{"rendered":"https:\/\/www.jsc-safe.com\/?p=2007"},"modified":"2024-05-23T16:29:26","modified_gmt":"2024-05-23T08:29:26","slug":"common-methods-of-weld-inspection","status":"publish","type":"post","link":"https:\/\/www.jsc-safe.com\/?p=2007","title":{"rendered":"Common Methods of Weld Inspection"},"content":{"rendered":"<h1>Common Methods of Weld Inspection<\/h1>\n<h2>1. Eddy Current<\/h2>\n<p>Eddy current testing (ET) is one of the non-destructive testing methods in industry<\/p>\n<p>Fast and effective detection of surface and subsurface cracks<\/p>\n<ul>\n<li>High detection rate without paint removal<\/li>\n<li>Wide coverage, fast scanning speed, save time<\/li>\n<li>Replace penetrant and magnetic particle testing\n<p><figure id=\"attachment_2010\" aria-describedby=\"caption-attachment-2010\" style=\"width: 501px\" class=\"wp-caption alignnone\"><img fetchpriority=\"high\" decoding=\"async\" class=\" wp-image-2010\" src=\"https:\/\/mlwbeysh49ih.i.optimole.com\/w:300\/h:187\/q:mauto\/ig:avif\/https:\/\/www.jsc-safe.com\/wp-content\/uploads\/2024\/05\/Eddy-Current.png\" alt=\"Eddy Current\" width=\"501\" height=\"312\" \/><figcaption id=\"caption-attachment-2010\" class=\"wp-caption-text\">Eddy Current<\/figcaption><\/figure><\/li>\n<\/ul>\n<h2>2. Industrial microscopes<\/h2>\n<p>Check the cross section of the weld using our imaging solution<\/p>\n<ul>\n<li>All the measurements are completed in one step to realize fast detection<\/li>\n<li>Suitable for t-joints, lap joints and corner joints and all weld sizes<\/li>\n<li>Calibrate the image to obtain reliable results\n<p><figure id=\"attachment_2011\" aria-describedby=\"caption-attachment-2011\" style=\"width: 503px\" class=\"wp-caption alignnone\"><img decoding=\"async\" class=\" wp-image-2011\" src=\"https:\/\/mlwbeysh49ih.i.optimole.com\/w:300\/h:194\/q:mauto\/ig:avif\/https:\/\/www.jsc-safe.com\/wp-content\/uploads\/2024\/05\/Industrial-microscopes.png\" alt=\"Industrial microscopes\" width=\"503\" height=\"325\" \/><figcaption id=\"caption-attachment-2011\" class=\"wp-caption-text\">Industrial microscopes<\/figcaption><\/figure><\/li>\n<\/ul>\n<h2>3. Regular ultrasound<\/h2>\n<p>High quality defect detection, very easy to use<\/p>\n<ul>\n<li>Its rugged, ergonomic design allows it to be used in challenging environments<\/li>\n<li>The intuitive interface is useful for both experienced and novice inspectors<\/li>\n<li>A full range of UT probes for detecting and measuring welding defects\n<p><figure id=\"attachment_2012\" aria-describedby=\"caption-attachment-2012\" style=\"width: 503px\" class=\"wp-caption alignnone\"><img data-opt-src=\"https:\/\/mlwbeysh49ih.i.optimole.com\/w:300\/h:180\/q:mauto\/ig:avif\/https:\/\/www.jsc-safe.com\/wp-content\/uploads\/2024\/05\/Regular-ultrasound.png\"  decoding=\"async\" class=\" wp-image-2012\" src=\"data:image/svg+xml,%3Csvg%20viewBox%3D%220%200%20300%20180%22%20width%3D%22300%22%20height%3D%22180%22%20xmlns%3D%22http%3A%2F%2Fwww.w3.org%2F2000%2Fsvg%22%3E%3Crect%20width%3D%22300%22%20height%3D%22180%22%20fill%3D%22transparent%22%2F%3E%3C%2Fsvg%3E\" alt=\"Regular ultrasound\" width=\"503\" height=\"302\" \/><figcaption id=\"caption-attachment-2012\" class=\"wp-caption-text\">Regular ultrasound<\/figcaption><\/figure><\/li>\n<\/ul>\n<h2>4. Remote visual inspection<\/h2>\n<p>Check hard-to-reach areas<\/p>\n<ul>\n<li>Best image quality for clear visualization<\/li>\n<li>With bright colors and clear images to improve the detection probability<\/li>\n<li>Evaluate welding damage effectively\n<p><figure id=\"attachment_2013\" aria-describedby=\"caption-attachment-2013\" style=\"width: 502px\" class=\"wp-caption alignnone\"><img data-opt-src=\"https:\/\/mlwbeysh49ih.i.optimole.com\/w:300\/h:187\/q:mauto\/ig:avif\/https:\/\/www.jsc-safe.com\/wp-content\/uploads\/2024\/05\/Remote-visual-inspection.png\"  loading=\"lazy\" decoding=\"async\" class=\" wp-image-2013\" src=\"data:image/svg+xml,%3Csvg%20viewBox%3D%220%200%20300%20187%22%20width%3D%22300%22%20height%3D%22187%22%20xmlns%3D%22http%3A%2F%2Fwww.w3.org%2F2000%2Fsvg%22%3E%3Crect%20width%3D%22300%22%20height%3D%22187%22%20fill%3D%22transparent%22%2F%3E%3C%2Fsvg%3E\" alt=\"Remote visual inspection\" width=\"502\" height=\"313\" \/><figcaption id=\"caption-attachment-2013\" class=\"wp-caption-text\">Remote visual inspection<\/figcaption><\/figure><\/li>\n<\/ul>\n<h2>5. Phased array ultrasound<\/h2>\n<p>Speed up the inspection process<\/p>\n<ul>\n<li>High-speed detection capability helps explain<\/li>\n<li>Compared with radiography, the examination time is reduced<\/li>\n<li>Immediate results enable immediate detection and repair of process problems\n<p><figure id=\"attachment_2014\" aria-describedby=\"caption-attachment-2014\" style=\"width: 501px\" class=\"wp-caption alignnone\"><img data-opt-src=\"https:\/\/mlwbeysh49ih.i.optimole.com\/w:300\/h:187\/q:mauto\/ig:avif\/https:\/\/www.jsc-safe.com\/wp-content\/uploads\/2024\/05\/Phased-array-ultrasound.png\"  loading=\"lazy\" decoding=\"async\" class=\" wp-image-2014\" src=\"data:image/svg+xml,%3Csvg%20viewBox%3D%220%200%20300%20187%22%20width%3D%22300%22%20height%3D%22187%22%20xmlns%3D%22http%3A%2F%2Fwww.w3.org%2F2000%2Fsvg%22%3E%3Crect%20width%3D%22300%22%20height%3D%22187%22%20fill%3D%22transparent%22%2F%3E%3C%2Fsvg%3E\" alt=\"Phased array ultrasound\" width=\"501\" height=\"312\" \/><figcaption id=\"caption-attachment-2014\" class=\"wp-caption-text\">Phased array ultrasound<\/figcaption><\/figure><\/li>\n<\/ul>\n<h2>6. X-ray fluorescence<\/h2>\n<p>On-site weld inspection and reliable material qualification<\/p>\n<ul>\n<li>Alloy verification helps ensure that the correct welding material is used<\/li>\n<li>Avoid corrosion, cracks and damage<\/li>\n<li>Analysis within seconds, no effect on weld\n<p><figure id=\"attachment_2015\" aria-describedby=\"caption-attachment-2015\" style=\"width: 504px\" class=\"wp-caption alignnone\"><img data-opt-src=\"https:\/\/mlwbeysh49ih.i.optimole.com\/w:300\/h:156\/q:mauto\/ig:avif\/https:\/\/www.jsc-safe.com\/wp-content\/uploads\/2024\/05\/X-ray-fluorescence.png\"  loading=\"lazy\" decoding=\"async\" class=\" wp-image-2015\" src=\"data:image/svg+xml,%3Csvg%20viewBox%3D%220%200%20300%20156%22%20width%3D%22300%22%20height%3D%22156%22%20xmlns%3D%22http%3A%2F%2Fwww.w3.org%2F2000%2Fsvg%22%3E%3Crect%20width%3D%22300%22%20height%3D%22156%22%20fill%3D%22transparent%22%2F%3E%3C%2Fsvg%3E\" alt=\"X-ray fluorescence\" width=\"504\" height=\"262\" \/><figcaption id=\"caption-attachment-2015\" class=\"wp-caption-text\">X-ray fluorescence<\/figcaption><\/figure><\/li>\n<\/ul>\n<p>Learn more our project quality managemet, QAQC and third party inspection (TPI), NDT practices thru below link.-<\/p>\n<p><a href=\"https:\/\/www.jsc-safe.com\/category\/oil-gas\/\" target=\"_blank\" rel=\"noopener\">https:\/\/www.jsc-safe.com\/category\/oil-gas\/<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Common Methods of Weld Inspection 1. Eddy Current Eddy current testing (ET) is one of the non-destructive testing methods in industry Fast and effective detection of surface and subsurface cracks High detection rate without paint removal Wide coverage, fast scanning speed, save time Replace penetrant and magnetic particle testing 2. Industrial microscopes Check the cross [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"aside","meta":{"footnotes":""},"categories":[4,31],"tags":[],"class_list":{"0":"post-2007","1":"post","2":"type-post","3":"status-publish","4":"format-aside","6":"category-ndt","7":"category-welding","8":"post_format-post-format-aside","9":"czr-hentry"},"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v22.1 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Common Methods of Weld Inspection<\/title>\n<meta name=\"description\" content=\"Common Methods of Weld Inspection - Eddy Current; Industrial microscopes; Regular ultrasound; Remote visual inspection; Phased array ultrasound; X-ray fluorescence.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.jsc-safe.com\/?p=2007\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Common Methods of Weld Inspection\" \/>\n<meta property=\"og:description\" content=\"Common Methods of Weld Inspection - Eddy Current; Industrial microscopes; Regular ultrasound; Remote visual inspection; Phased array ultrasound; X-ray fluorescence.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.jsc-safe.com\/?p=2007\" \/>\n<meta property=\"og:site_name\" content=\"JSC SAFE\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/profile.php?id=100006428552877\" \/>\n<meta property=\"article:published_time\" content=\"2024-05-23T08:29:26+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/mlwbeysh49ih.i.optimole.com\/w:300\/h:187\/q:mauto\/ig:avif\/https:\/\/www.jsc-safe.com\/wp-content\/uploads\/2024\/05\/Eddy-Current.png\" \/>\n<meta name=\"author\" content=\"jscadmin\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"jscadmin\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"3 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/www.jsc-safe.com\/?p=2007#article\",\"isPartOf\":{\"@id\":\"https:\/\/www.jsc-safe.com\/?p=2007\"},\"author\":{\"name\":\"jscadmin\",\"@id\":\"https:\/\/www.jsc-safe.com\/#\/schema\/person\/475b6cef7eaf4f9c1b6874d5d6504377\"},\"headline\":\"Common Methods of Weld Inspection\",\"datePublished\":\"2024-05-23T08:29:26+00:00\",\"dateModified\":\"2024-05-23T08:29:26+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/www.jsc-safe.com\/?p=2007\"},\"wordCount\":312,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\/\/www.jsc-safe.com\/#organization\"},\"articleSection\":[\"NDT\",\"Welding\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\/\/www.jsc-safe.com\/?p=2007#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.jsc-safe.com\/?p=2007\",\"url\":\"https:\/\/www.jsc-safe.com\/?p=2007\",\"name\":\"Common Methods of Weld Inspection\",\"isPartOf\":{\"@id\":\"https:\/\/www.jsc-safe.com\/#website\"},\"datePublished\":\"2024-05-23T08:29:26+00:00\",\"dateModified\":\"2024-05-23T08:29:26+00:00\",\"description\":\"Common Methods of Weld Inspection - Eddy Current; Industrial microscopes; Regular ultrasound; Remote visual inspection; Phased array ultrasound; X-ray fluorescence.\",\"breadcrumb\":{\"@id\":\"https:\/\/www.jsc-safe.com\/?p=2007#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.jsc-safe.com\/?p=2007\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.jsc-safe.com\/?p=2007#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"\u9996\u9875\",\"item\":\"https:\/\/www.jsc-safe.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Common Methods of Weld Inspection\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.jsc-safe.com\/#website\",\"url\":\"https:\/\/www.jsc-safe.com\/\",\"name\":\"JSC SAFE\",\"description\":\"Engineering &amp; Fabrication- PM, NDT, QAQC, TPI\",\"publisher\":{\"@id\":\"https:\/\/www.jsc-safe.com\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.jsc-safe.com\/?s={search_term_string}\"},\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.jsc-safe.com\/#organization\",\"name\":\"JSC SAFE\",\"url\":\"https:\/\/www.jsc-safe.com\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.jsc-safe.com\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/mlwbeysh49ih.i.optimole.com\/w:auto\/h:auto\/q:mauto\/ig:avif\/https:\/\/www.jsc-safe.com\/wp-content\/uploads\/2024\/03\/cropped-JSC_LOGO_2022-removebg-preview.png\",\"contentUrl\":\"https:\/\/mlwbeysh49ih.i.optimole.com\/w:auto\/h:auto\/q:mauto\/ig:avif\/https:\/\/www.jsc-safe.com\/wp-content\/uploads\/2024\/03\/cropped-JSC_LOGO_2022-removebg-preview.png\",\"width\":500,\"height\":200,\"caption\":\"JSC SAFE\"},\"image\":{\"@id\":\"https:\/\/www.jsc-safe.com\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/www.facebook.com\/profile.php?id=100006428552877\",\"https:\/\/www.linkedin.com\/in\/kenneth-ren-0bbb04102\/\"]},{\"@type\":\"Person\",\"@id\":\"https:\/\/www.jsc-safe.com\/#\/schema\/person\/475b6cef7eaf4f9c1b6874d5d6504377\",\"name\":\"jscadmin\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.jsc-safe.com\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/72254946e33ae8216c269d336f048b53b16f028f438c7b85bef9fa549fbf4e2a?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/72254946e33ae8216c269d336f048b53b16f028f438c7b85bef9fa549fbf4e2a?s=96&d=mm&r=g\",\"caption\":\"jscadmin\"},\"url\":\"https:\/\/www.jsc-safe.com\/?author=2\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Common Methods of Weld Inspection","description":"Common Methods of Weld Inspection - Eddy Current; Industrial microscopes; Regular ultrasound; Remote visual inspection; Phased array ultrasound; X-ray fluorescence.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.jsc-safe.com\/?p=2007","og_locale":"en_US","og_type":"article","og_title":"Common Methods of Weld Inspection","og_description":"Common Methods of Weld Inspection - Eddy Current; Industrial microscopes; Regular ultrasound; Remote visual inspection; Phased array ultrasound; X-ray fluorescence.","og_url":"https:\/\/www.jsc-safe.com\/?p=2007","og_site_name":"JSC SAFE","article_publisher":"https:\/\/www.facebook.com\/profile.php?id=100006428552877","article_published_time":"2024-05-23T08:29:26+00:00","og_image":[{"url":"https:\/\/mlwbeysh49ih.i.optimole.com\/w:300\/h:187\/q:mauto\/ig:avif\/https:\/\/www.jsc-safe.com\/wp-content\/uploads\/2024\/05\/Eddy-Current.png"}],"author":"jscadmin","twitter_card":"summary_large_image","twitter_misc":{"Written by":"jscadmin","Est. reading time":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.jsc-safe.com\/?p=2007#article","isPartOf":{"@id":"https:\/\/www.jsc-safe.com\/?p=2007"},"author":{"name":"jscadmin","@id":"https:\/\/www.jsc-safe.com\/#\/schema\/person\/475b6cef7eaf4f9c1b6874d5d6504377"},"headline":"Common Methods of Weld Inspection","datePublished":"2024-05-23T08:29:26+00:00","dateModified":"2024-05-23T08:29:26+00:00","mainEntityOfPage":{"@id":"https:\/\/www.jsc-safe.com\/?p=2007"},"wordCount":312,"commentCount":0,"publisher":{"@id":"https:\/\/www.jsc-safe.com\/#organization"},"articleSection":["NDT","Welding"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.jsc-safe.com\/?p=2007#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.jsc-safe.com\/?p=2007","url":"https:\/\/www.jsc-safe.com\/?p=2007","name":"Common Methods of Weld Inspection","isPartOf":{"@id":"https:\/\/www.jsc-safe.com\/#website"},"datePublished":"2024-05-23T08:29:26+00:00","dateModified":"2024-05-23T08:29:26+00:00","description":"Common Methods of Weld Inspection - Eddy Current; Industrial microscopes; Regular ultrasound; Remote visual inspection; Phased array ultrasound; X-ray fluorescence.","breadcrumb":{"@id":"https:\/\/www.jsc-safe.com\/?p=2007#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.jsc-safe.com\/?p=2007"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.jsc-safe.com\/?p=2007#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"\u9996\u9875","item":"https:\/\/www.jsc-safe.com\/"},{"@type":"ListItem","position":2,"name":"Common Methods of Weld Inspection"}]},{"@type":"WebSite","@id":"https:\/\/www.jsc-safe.com\/#website","url":"https:\/\/www.jsc-safe.com\/","name":"JSC SAFE","description":"Engineering &amp; Fabrication- PM, NDT, QAQC, TPI","publisher":{"@id":"https:\/\/www.jsc-safe.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.jsc-safe.com\/?s={search_term_string}"},"query-input":"required name=search_term_string"}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.jsc-safe.com\/#organization","name":"JSC SAFE","url":"https:\/\/www.jsc-safe.com\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.jsc-safe.com\/#\/schema\/logo\/image\/","url":"https:\/\/mlwbeysh49ih.i.optimole.com\/w:auto\/h:auto\/q:mauto\/ig:avif\/https:\/\/www.jsc-safe.com\/wp-content\/uploads\/2024\/03\/cropped-JSC_LOGO_2022-removebg-preview.png","contentUrl":"https:\/\/mlwbeysh49ih.i.optimole.com\/w:auto\/h:auto\/q:mauto\/ig:avif\/https:\/\/www.jsc-safe.com\/wp-content\/uploads\/2024\/03\/cropped-JSC_LOGO_2022-removebg-preview.png","width":500,"height":200,"caption":"JSC SAFE"},"image":{"@id":"https:\/\/www.jsc-safe.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/profile.php?id=100006428552877","https:\/\/www.linkedin.com\/in\/kenneth-ren-0bbb04102\/"]},{"@type":"Person","@id":"https:\/\/www.jsc-safe.com\/#\/schema\/person\/475b6cef7eaf4f9c1b6874d5d6504377","name":"jscadmin","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.jsc-safe.com\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/72254946e33ae8216c269d336f048b53b16f028f438c7b85bef9fa549fbf4e2a?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/72254946e33ae8216c269d336f048b53b16f028f438c7b85bef9fa549fbf4e2a?s=96&d=mm&r=g","caption":"jscadmin"},"url":"https:\/\/www.jsc-safe.com\/?author=2"}]}},"_links":{"self":[{"href":"https:\/\/www.jsc-safe.com\/index.php?rest_route=\/wp\/v2\/posts\/2007","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.jsc-safe.com\/index.php?rest_route=\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.jsc-safe.com\/index.php?rest_route=\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.jsc-safe.com\/index.php?rest_route=\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.jsc-safe.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=2007"}],"version-history":[{"count":4,"href":"https:\/\/www.jsc-safe.com\/index.php?rest_route=\/wp\/v2\/posts\/2007\/revisions"}],"predecessor-version":[{"id":2017,"href":"https:\/\/www.jsc-safe.com\/index.php?rest_route=\/wp\/v2\/posts\/2007\/revisions\/2017"}],"wp:attachment":[{"href":"https:\/\/www.jsc-safe.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=2007"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.jsc-safe.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcategories&post=2007"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.jsc-safe.com\/index.php?rest_route=%2Fwp%2Fv2%2Ftags&post=2007"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}